http://WWW.ASNSERVICES.CO.IN
PARKINGMANAGEMENTSYSTEMS 5a549ebce2f63f0b7806eedd False 58 12
OK
background image not found
Updates
2018-07-28T06:24:32
update image not found
Tripod Turnstile Supplier in Delhi NCR Semi Automatic Tripod Turnstile with Access Card Reader :ASN-900 Single direction or double direction for option A valid lock action can allow one passage at one time Normally open--- the machine will unlock when a valid signal is received The arm falls down automatically in case of power off LED digital function (optional) Easy to be integrated with Biometric , magnetic card, barcode card, ID card, IC card, etc with Biometric Reader
2018-07-28T06:22:29
update image not found
Automatic Boom Barrier Supplier in Delhi NCR ASN’s Automatic Boom Barriers offer efficient security at exit and entry points of factories, office complexes, parking lots, toll plazas, or any roadway entry where medium to heavy traffic is expected. The boom barrier is aesthetically designed with smooth and modern looks. Features of the boom barrier include an inbuilt anti-crush safety sensor, which suspends the motion of the boom, should it meet any obstruction. Optional beam sensor provides further protection to vehicles. Auto-close of the boom barrier can be programmed through the controller. Duration of fast and slow speeds is programmed at the time of installation, according to the length of the boom and frequency of traffic expected. However its electronic control panel is designed to accept signals from various controls and safety accessories.
2018-07-28T06:21:52
update image not found
Automatic Parking Management System Supplier in Delhi NCR The present circumstances in major cities and towns are the ever-growing human population as well as vehicle population. This has given rise to the need for multi level parking lots. People be likely to get frustrated in finding a parking spot in huge parking lots if not guided properly. ASN’S Parking Management Solutions helps people find parking spots with easiness at real time as well as provide a smooth stream of traffic to increase the revenue collection. Once a vehicle enters a parking lot it can be guided with the help of sensors or over head lights on the availability of parking spots. For instance, a green light indicates available spot where as a red light would indicate a parked spot. Hence the driver can navigate himself to the available spot. This reduces the craving on extra attendants and reduces operational costs. Technologically advanced RFID tag based system provided by ASN is an inimitable mode of collecting parking revenue. Commuters fill certain amount of money in the tags through POS facilities. It facilitates for cashless transactions that would otherwise be in the hands of an operator. A RFID tag fitted vehicle can enter a parking lot; the tag gets validated by RFID readers along with Automatic Number Plate Recognition cameras at the entry point. When the vehicle is at exit point, another RFID reader detects the time spent in the parking lot allocates it in a price bracket and automatically deducts the relevant amount from the tag. In case of any violations the vehicle can be guided to the POS competence where he can pay the penalties.
2018-07-20T13:37:42
update image not found
Loop Detector Supplier in Delhi NCR Technical Data: Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10 mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide"). - Operation and Indication: While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered. - Output Relay: The relay2 is pulse output. If DIP7 is "OFF" site, when a vehicle is detected passing over the inductive loop, the relay is energized( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. If DIP7 is "ON" site, when a vehicle is detected departing the loop, the relay is energized ( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. The relay 1 is presence output. When a vehicle is detected passing over the inductive loop, the relay is energized( Pin5 and Pin6 are shorted) until the vehicle is detected departing the loop. - Presence Time: The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is configured as follows: OFF:Limited Presence ( 10 minutes), ON:Permanent Presence. - Reset Switch : The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to re-tune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.
2018-07-20T13:32:32
update image not found
Tripod Turnstile Supplier in Delhi NCR Semi Automatic Tripod Turnstile :ASN-900 Single direction or double direction for option A valid lock action can allow one passage at one ti me Normally open--- the machine will unlock when a valid signal is received The arm falls down automatically in case of power off LED digital function (optional) Easy to be integrated with Biometric , magnetic card, bar code card, ID card, IC card, etc
false