http://WWW.ASNSERVICES.CO.IN
PARKINGMANAGEMENTSYSTEMS 5a549ebce2f63f0b7806eedd False 58 12
OK
background image not found
Found Update results for
'housing 304 stainless'
5
TRIPOD TURNSTILE Functions and Features: 1.Special wheel mechanism is used here to realize the function of fixing and also unfixing all the parts of the turnstile 2.All the system runs stable with little noise and no mechanical impact 3.It can self-check and alarm which will be make it convenient to use 4.Several ways of working molds can be chosen at your request 5.It can work double direction, or one direction permitted, one forbidden, or one direction charged, one for free, and all the working molds can be set by the buttons in the main control board 6.Beam falling and lifting can be controlled in far distance so to satisfy the special requirement of the users and the request of fire protection 7.Beam can be lifted and fall when electricity is cut-off 8.It has the standard electrical interface which can be connected with various kinds of reader and writer equipment 9.So all the functions can be realized in one integration machine and can be controlled and managed by the computer in the far distance 10.The number of the persons who have passed by can be counted automatically which can also be displayed in LED 11.Direction guide lights are in the turnstile to tell you which direction can go or which can not 12.You can set the function with or without card reading memory according to your requirement 13.The number of the persons who can pass by the turnstile can be set to meet the requirement of some special occasions 14.After reading the card, if the person who punched the card does not pass it within the set time, then this chance to access will be canceled, and the set time can be changed according to your request. Specifications; Model ASN 900 Manual, Semi or Full-auto Full-auto Material of Housing 304 Stainless Steel Dimension of Housing 420*380*1000 Max Load-bearing of Pole 50kg Driving Force of Pole 3kg Rotating Direction Double Direction Power Supply 220v±10%, 110±10% Frequency 50/60HZ Working Voltage of Motor DC12V Rated Power 50w Driving Motor DC Motor Transit Speed 30~40 person/min Working Temperature -25°C~55°C Working Environment Indoor/outdoor(Shelter) Relative Humidity ≤95%
Tripod Turnstile Supplier in Delhi NCR Ensuring security and crowd management at the entrance in areas such as railway platforms, passenger terminals, sports stadiums, Corporate Parks etc requires a turnstile. So, in order to manage crowds at busy hours and restrict entries effectively, ASN SERVICES PVT LTD presents Slim Tripod Turnstile. Features The turnstile has electro mechanical mechanism brushless DC Motor. 3 x 120 degree rotating tripod arms Bi-directional operational control The turnstile has a self-centering mechanism with hydraulic damping Integrated with access control Case work available in mild steel powder coated or stainless steel 304, with stainless steel arms Lockable casing 380mm or 500mm walkway (standard is 380mm) Designed for pedestrian entrance control, these turnstile gates open only for those with authorised access. Its rotating arms allow one person through at a time. The tripod turnstile’s rotating arms allows one person through at a time. Related Information Optional Features: The turnstile has an automatic drop arm feature in case of emergency The auto swirl of the tripod turnstile is Sensor based Case work - stainless steel-316 ASN SERVICES PVT LTD. Turnstile has indoor applications like corporate offices, IT parks, airports, large business facilities etc.
Boom Barrier with RFID Reader in Delhi NCR UHD RFID Entrance System with Automatic Boom Barrier - are well-liked in housing complex, corporate tower, Industry etc. where many vehicles enter & exit in the complex daily basis. In this system UHF RFID (Ultra High Frequency Radio frequency Identification) Cards / or Tags / or Stickers are pasted on the Vehicle’s wind screen. One UHF Reader is mounted at the Entry & Exit Gates. These readers can read the UHD Cards / stickers / tags from 10~15 meters distance and OPENS the Gate. This system avoids corporal substantiation of registered vehicles.
Loop Detector Supplier in Delhi NCR Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide").
Loop Detector Supplier in Delhi NCR Technical Data: Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10 mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide"). - Operation and Indication: While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered. - Output Relay: The relay2 is pulse output. If DIP7 is "OFF" site, when a vehicle is detected passing over the inductive loop, the relay is energized( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. If DIP7 is "ON" site, when a vehicle is detected departing the loop, the relay is energized ( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. The relay 1 is presence output. When a vehicle is detected passing over the inductive loop, the relay is energized( Pin5 and Pin6 are shorted) until the vehicle is detected departing the loop. - Presence Time: The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is configured as follows: OFF:Limited Presence ( 10 minutes), ON:Permanent Presence. - Reset Switch : The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to re-tune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.
1
false