http://WWW.ASNSERVICES.CO.IN
PARKINGMANAGEMENTSYSTEMS 5a549ebce2f63f0b7806eedd False 58 12
OK
background image not found
Found Update results for
'convenient'
5
High Speed Boom Barrier in Delhi/NCR Boom barriers are the perfect equipment for effective parking management system. It can be used in the entry and exit points of parking places factories, stations, malls, Residential Society Gates, toll plazas and so many other places where a possibility of medium to heavy traffic has to be controlled to get convenient security system to prevent unauthorized access in the premises.
Turnstile/Flap Barrier Supplier in Delhi/NCR Features and Functions: • Special wheel mechanism is used here to realize the function of fixing and also unfixing all the parts of the turnstile • All the system runs stable with little noise and no mechanical impact • It can self-check and alarm which will be make it convenient to use • Several ways of working molds can be chosen at your request • It can work bi-direction, or one direction permitted, one forbidden, or one direction charged, one for free, and all the working molds can be set by the buttons in the main control board • Beam falling and lifting can be controlled in far distance so to satisfy the special requirement of the users and the request of fire protection • Beam can be lifted and fall when electricity is cut-off • It has the standard electrical interface which can be connected with various kinds of reader and writer equipment • So all the functions can be realized in one integration machine and can be controlled and managed by the computer in the far distance • The number of the persons who have passed by can be counted automatically which can also be displayed in LED • Direction-guide lights are in the turnstile to tell you which direction can go or which cannot • You can set the function with or without card-reading memory according to your requirement. • The number of the persons who can pass by the turnstile can be set to meet the requirement of some special occasions • After reading the card, if the person who punched the card does not pass it within the set time, then this chance to access will be canceled, and the set time can be changed according to your request.
Loop Detector Supplier in Delhi NCR Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide").
Loop Detector Supplier in Delhi NCR Technical Data: Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10 mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide"). - Operation and Indication: While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered. - Output Relay: The relay2 is pulse output. If DIP7 is "OFF" site, when a vehicle is detected passing over the inductive loop, the relay is energized( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. If DIP7 is "ON" site, when a vehicle is detected departing the loop, the relay is energized ( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. The relay 1 is presence output. When a vehicle is detected passing over the inductive loop, the relay is energized( Pin5 and Pin6 are shorted) until the vehicle is detected departing the loop. - Presence Time: The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is configured as follows: OFF:Limited Presence ( 10 minutes), ON:Permanent Presence. - Reset Switch : The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to re-tune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.
Tripod Turnstile Supplier In Delhi NCR ASN-1000  Auto replacement function, reposition after person pass by  Anti tail function auto-lock once turn 120°  Arms auto drop when power off , insure unblocked when accident  Standard electronic interface, remote control through internet which is also could connect variety card readers and receive relay signal to work  Diverse control mode optional, changeable due to varying, convenient for your manage  Auto alert error function, comfort for user maintain and operate  Manual button or remote control , Bi-directional passage  Open signal with memory or without set function  Red and green light to show pass or stop, leisure to exit and entrance. Key Features  Cabinet & Internal Structure is in 304 SS grade.  Length of Swing Arm 500 to 550mm  With drop arm features  Unlock Time 0.2 second  Passing Speed 30-40 Person/Min.  Passing Width 500-550mm  Power Supply AC220, 50/60Hz  Operational Voltage Motor (24V)  Working Temp (-25°C to +75°C)  Protection Level 55IP  Electro Mechanical Drive DC  Dimension Excluding Bars (H980xW(480-1200)xD280mm)  Maximum power consumption 60W
1
false