http://WWW.ASNSERVICES.CO.IN
PARKINGMANAGEMENTSYSTEMS 5a549ebce2f63f0b7806eedd False 58 12
OK
background image not found
Found Update results for
'consumption'
5
#UHF Long Range Integrative Reader Brief Introduction: The products can be compatible with multi-protocol, integrated design, quickly read, multi-tag read, proof-water, can be used widely in RFID systems, the mainly applying site is:  Logistics and warehouse Management: Goods flow, warehouse management and the flowing management of mail, parcel, luggage.  Intelligent parking Management: Parking management and automatic charge  Productive lines Management: Production process fixed identification  Product counterfeit-proof inspection: Using memory’s write-protect functions inside tags, and identifying with true-false of products.  Other fields: Used widely in club management, library, student school, consumption management, time management, dinner management, pool management. Technical Parameters : Model ASN 088 Protocol ISO18000-6B ; ISO18000-6C ; EPC GEN2 Frequency Range Standard ISM 902~928MHz or ISM 865~868MHz, other frequency available Operation Mode FHSS RF Power 0~30dBm, software adjustable Reading Speed Software Programmable , Average Reading per 64Bits<6ms Reading Mode Timing or Touch, Software Programmable Data Ports Standard Wiegand26/34, RS485 ; RS232 ; Software Programmable WIFI interface Custom-made RJ45 Data Input Port Trigger input one, anti-collision and multi-reading Reading Range 12m Reading Clue Buzzer Antenna Built-in line polarization Antenna ; Gain:12dbi Power Supply DC: 9V (Power Adapter), DC+12 Dimension 440mm×440mm×50mm Weight 5 Kg Operation Temp 20℃~80℃
UHF RFID Long Range Reader Brief Introduction: The products can be compatible with multi-protocol, integrated design, quickly read, multi-tag read, proof-water, can be used widely in RFID systems, the mainly applying site is:  Logistics and warehouse Management: Goods flow, warehouse management and the flowing management of mail, parcel, luggage.  Intelligent parking Management: Parking management and automatic charge  Productive lines Management: Production process fixed identification  Product counterfeit-proof inspection: Using memory’s write-protect functions inside tags, and identifying with true-false of products.  Other fields: Used widely in club management, library, student school, consumption management, time management, dinner management, pool management. Technical Parameters : Model ASN 088 Protocol ISO18000-6B ; ISO18000-6C ; EPC GEN2 Frequency Range Standard ISM 902~928MHz or ISM 865~868MHz, other frequency available Operation Mode FHSS RF Power 0~30dBm, software adjustable Reading Speed Software Programmable , Average Reading per 64Bits<6ms Reading Mode Timing or Touch, Software Programmable Data Ports Standard Wiegand26/34, RS485 ; RS232 ; Software Programmable WIFI interface Custom-made RJ45 Data Input Port Trigger input one, anti-collision and multi-reading Reading Range 12m Reading Clue Buzzer Antenna Built-in line polarization Antenna ; Gain:12dbi Power Supply DC: 9V (Power Adapter), DC+12 Dimension 440mm×440mm×50mm Weight 5 Kg Operation Temp 20℃~80℃
Brief Introduction: The products can be compatible with multi-protocol, integrated design, quickly read, multi-tag read, proof-water, can be used widely in RFID systems, the mainly applying site is:  Logistics and warehouse Management: Goods flow, warehouse management and the flowing management of mail, parcel, luggage.  Intelligent parking Management: Parking management and automatic charge  Productive lines Management: Production process fixed identification  Product counterfeit-proof inspection: Using memory’s write-protect functions inside tags, and identifying with true-false of products.  Other fields: Used widely in club management, library, student school, consumption management, time management, dinner management, pool management.
Loop Detector Supplier in Delhi NCR Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide").
Loop Detector Supplier in Delhi NCR Technical Data: Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC ( See the label on the detector) Voltage tolerance AC: +10% / -15% Voltage tolerance DC: ±15% Power Consumption: 4.5VA Output relays: 240V/5A Operating temperature: -20°C to +65°C Storage temperature: -40°C to +85°C Frequency range: 20 kHz to 170 kHz Reaction time: 100ms Signal holding time: Unlimited Sensitivity: Adjustable in 3 increments Loop inductance: Total loop plus connection wiring: 50μH to 1000μH. Ideal is 100μH to 300μH Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter Size of Housing: 78x40x108 mm (L x W x H) - Install Detector: The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10 mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide"). - Operation and Indication: While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered. - Output Relay: The relay2 is pulse output. If DIP7 is "OFF" site, when a vehicle is detected passing over the inductive loop, the relay is energized( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. If DIP7 is "ON" site, when a vehicle is detected departing the loop, the relay is energized ( Pin3 and Pin4 is shorted) and de-energized ( Pin3 and Pin4 is opened) after 500ms. The relay 1 is presence output. When a vehicle is detected passing over the inductive loop, the relay is energized( Pin5 and Pin6 are shorted) until the vehicle is detected departing the loop. - Presence Time: The presence time may be set to permanent presence or to limited presence. In permanent presence mode the detector will continuously compensate for all environmental changes whilst there is a vehicle present over the loop, the presence mode is set with DIP8 Switch and is configured as follows: OFF:Limited Presence ( 10 minutes), ON:Permanent Presence. - Reset Switch : The detector automatically tunes to the inductive loop connected to it when the power is applied, whether on initial installation or after any break in power supply. Should it be necessary to re-tune the detector, as may be required after changing any of the switches or after moving the detector from one installation to another, momentary operation of the RESET switch will initiate the automatic tuning cycle.
1
false